ATTACHMENT INSTRUCTIONS FOR
FLUSH MOUNT No. 4602 (FOR WALL OR CEILING)
- UNSCREW THE 3 GLASS HOLDERS (I) AND PUT THE GLASS
(H)ASIDE.
- ATTACH THE CROSS BAR (B) TO THE JUNCTION BOX (A) (NOT
SUPPLIED).
- CONNECT THE SOCKET WIRE TO THE ELECTRICAL WIRES IN THE
JUNCTION BOX (A) WITH WIRE NUTS (NOT SUPPLIED).
- SCREW THE NIPPLE (D) INTO THE CROSS BAR (B) 1/4 OF THE
WAY.
- INSERT THE LAMP PLATE (E) ONTO THE NIPPLE (D) AND SCREW
THE NIPPLE COVER (F) ONTO THE NIPPLE (D).
- INSERT THE 200W HALOGEN BULB (G) IN BETWEEN THE SOCKETS (DO THIS BY PUSHING ONE SIDE OF THE BULB INTO ONE SOCKET
FIRST,THEN CONTINUE TO DO THE SAME FOR THE OTHER SIDE. (THIS TYPE OF BULB USE SOCKET THAT
MADE OUT OF 2 PARTS).
- NEVER TOUCH THE BULB WITH BARE HANDS ALWAYS
HOLD IT WITH CLEAN PAPER. OIL LEFT BY YOUR
FINGERPRINT MAY CAUSE THE THE BULB TO EXPLODE WHEN HEATED. FINGER MARKS LEFT ON THE BULB
SHOULD BE WIPED OFF WITH ALCOHOL. CAUTION: HALOGEN BULBS PRODUCE HIGH INTENSITY HEAT.
- REATTACH THE GLASS (H) TO THE LAMP PLATE (E) WITH THE 3
GLASS HOLDERS (I).
- YOUR NEW HALOGEN LAMP MAY "SMOKE" WHEN FIRST
USED. IT IS NORMAL FOR THE BULB TO BURN OUT ALL EXCESS MATERIAL LEFT ON IT FOR THE FIRST
FEW MINUTES OF OPERATION.
|